Ticket 20180131_2
Ticket Number: | 20180131_2 | Ticket State: | CLOSED | ||
---|---|---|---|---|---|
Ticket Opened: | 2018-01-31 17:36 | Ticket Closed: | 2018-02-14 08:39 | ||
Ticket Description: | Scheduled fiber relocation @EPFL (14.2.2018) | ||||
Scheduled Starttime: | 2018-02-14 07:00:00 | Scheduled Endtime: | 2018-02-14 08:00:00 |
Problem Description:
EPFL is renewing their central communication room. There will be a large scale 1 hour fiber interruption on February 14, while they move the cable terminations (ODFs) to a new rack.Only very few service interruptions are expected thanks to the availability of redundant paths. However, EPFL LABA and a temporarily established link for CFF to CM 1 364 Esplanade (@EPFL) will be completely unavailable during the work.
Affected:
From 2018-02-14 07:00 until 2018-02-14 08:00Impact: Total loss of connectivity
Service: P2P/OPN
Sites: EPFL-CBT-el2-ge2, EPFL-IMT-el2-ne2, EPFL-LABA-el2-ba1
From 2018-02-14 07:00 until 2018-02-14 08:00
Impact: no more redundancy
Service: P2P/OPN
Sites: CERN-CNAF-LHCOPN-002, EPFL-Lausanne, Sommet-BUL, Sommet-CL, Sommet-GL
From 2018-02-14 07:00 until 2018-02-14 08:00
Impact: no more redundancy
Service: network access
Sites: CHUV, EPFL, Sommet, UNIL, VSNET
Actions:
2018-02-14 07:35
All ODFs moved to the new rack, all links up and running.
For all questions about this ticket, please send mail to noc@switch.ch